VarTech's Class 1, Division 2, Groups A,
B, C, and D industrial workstations and LCD computers, use
a Type Z purge system which operates by forcing air or an
inert gas through the enclosure until all of the hazardous
gas is removed (purging). After purging, constant pressure
is maintained within the enclosure & equipment inside
the enclosure can be energized.
Z Type Purge System for Class
1, Division 2, Groups A,B,C,D
This system is for use in Class I, Division
2, Groups A, B, C, and D. It regulates and monitors pressure
within sealed (protected) enclosure(s), in order to remove
and prevent flammable gas or vapor accumulations. The system
accomplishes four air exchanges and maintains a "safe"
(0.25") pressure.
* Includes form "C" contacts
for audible or visual alarm systems.
* UL, cUL & FM classified
* In accordance with the NEC - NFPA 70, Article 500,
NFPA 496 and ISA 12.4.
* Enclosure volumes to 15 cu. Ft.
* Side, Bottom, and Top mountings available
Contact
a representative for more information on intrinsically
safe & purged control monitors, computers and workstations
for Haz Loc areas.
|