VarTech's Class 2, Division 2, Groups E,
F, and G industrial workstations and LCD computers, use a
Type Z automatic pressurization system which operates by pressurizing
the systems air so no ignitable materials can enter. Once
the system is stabilized and confirmed, and constant pressure
is maintained within the system, the enclosure is energized.
Z Type Purge System for Class
2, Div 2, Groups E, F, and G
This system is for use in Class 2, Division
2, Groups E, F, and G. It regulates and monitors pressure
within sealed (protected) enclosure(s), in order to remove
and prevent flammable gas or vapor accumulations. The system
accomplishes four air exchanges and maintains a "safe"
(0.25") pressure.
* Includes form "C" contacts for
audible or visual alarm systems.
* UL, cUL & FM classified
* In accordance with the NEC - NFPA 70, Article 500,
NFPA 496 and ISA 12.4.
* Enclosure volumes to 15 cu. Ft.
* Side, Bottom, and Top mountings available