One Drop Fill (ODF)
In the traditional LCD injection method,
the cell will be vacuum filled by capillary attraction after
the two glass substrates are assembled. Such injection method
has the drawbacks of wasting time and LC material. The newly
introduced ODF method is to drop the LC directly on the glass
substrate prior to the assembling of the two substrates.
This innovative method can save a great deal of time and LC
material that has a competitive edge particularly for large
size panel. For example, it requires about 5 days to fill
the LC for a 30 inches panel according to the traditional
method, but it only needs 5 minutes by adoption of the ODF
method. Thereby the consumption of LC material can be reduced
to approximately 40% as compared to the traditional method. |