VT752ESC: 17" Purged Enclosed Computer for Class 2 Div 1 Environments

FEATURES
- Designed to Meet Class 2
Division 1
- Purged pressure switch
- NEMA 4x sealed enclosure
- Water proof and dust proof
- Stainless steel construction
- Easy latch access
- Hard-anodized aluminum
heat sink
- Closed loop thermal cooling for high heat environments
- Flexible mounting options
- Optional Non-Incendive
Keyboard/Mouse

CONTACT

HEADQUARTERS
11529 Sun Belt Ct.
Baton Rouge, Louisiana  70809

Phone
800.223.8050
International 001.225.298.0300
Fax
225.297.2440

E-mail
sales@vartechsystems.com

Website
www.vartechsystems.com

_____________________

Purge System w/ Pressure Switch (Class 1, Div 1 Protection)

Regulator Body
Zinc w/ Enamel Finish

Regulator Handle
Polycarbonate

Enclosure Pressure Gauge
Alum. w/ Enamel Finish

Tube Fittings
316 SS Forged Body

Tubing
316 SS 1/4" .035 Welded

System Nameplates
Silk screened Lexan® & SS

Fastener Hardware
Alum. & Stainless Steel

Mounting Plate
316 14 Ga #3 Brush SS

EXP Pressure Switch Body
Anodized Cast Aluminum

Enclosure warning

Nameplate
Silk screened SS

Lexan® is a registered trademark of the
General Electric Company.

 

The VT752ESC is a NEMA 4X (IP66) HMI system designed to meet Class 2, Div 1 protection. The purge system uses a pressure switch to automatically trigger alarms in case of pressure loss.
Durable
The VT752ESC can easily handle the punishment of harsh computing environments. They are proven tough in real world applications such as industrial production areas, outdoor kiosks and public terminals. The VT752ESC chassis has no external vents, so nothing can get under its skin, including dust, dirt, moisture, oil, chemicals or other harsh contaminants. A hard-anodized aluminum heat exchanger and internal heat management system keep it cool in environments where ambient temperatures approach 50°C (122°F)-- without using outside air.

Product Features

Display
17", 1280 x 1024 SXGA

Processor
Powerful T4500 2.30 GHz 800MHz FSB Intel Dual Core

BIOS
Award PnP 4MB Flash ROM BIOS

O/S
Windows XP Professional (optional Windows Embedded Standard)

System Memory
SO-DIMM DDRII 667/533/400 2 GB

Graphics
Integrated VGA Engine in chipset (Intel
GMA 950)

LAN
Integrated Intel Gigabit PCI Express LAN Chip

Hard Drive
500 GB Fast Access Disk Drive

Power Input
100-240VAC 1.5A 50/60 HZ

Power Connector
Standard Power Inlet (IEC320 C14)

Dimensions
20" W x 18" D x 11" H

Expansion Slots
Mini PCI x 1

DVD Drive (E-IDE / ATAPI)
DVD-R, DVD+R, DVD-RW, DVD+RW, DVDR
DL, DVD+R9, CD-R, CD-RW

I/O Ports
1 Realtek ALC882 HD Audio CODEC
PS/2 Keyboard Connector x 1
PS/2 Mouse Connector x 1
AC Adapter Connector x 1
DVI Port x 1
S-Video Out Port x 1
COM Port x 1
USB 2.0 Port x 4
1394 Port x 1
RJ45 LAN Port x 1
Line In / SPDIF In x 1
Speaker Out x 1
MIC In x 1
Center / Subwoofer x 1
Rear Surround / SPDIF Out x 1
Side Surround x 1

Temperature
Operational: 5° - 55°C (41° to 131°F)

Construction
316 stainless steel
Anodized aluminum heat sink
10" handles
IP67 - NEMA 4X (IP66), waterproof and
dustproof

Enclosure Only:
18" H x 20" W x 11" D
66 lb
Purge Kit Only:
20" (H) x 11" (W) x 10.5" (D), 38 lb

Product Options

Purge System Mounting to Side (L/R), Top or Bottom

Windows Embedded Standard

_____________________________________________________________

X Type Purge System w/ Pressure Switch (Class 2, Div 1 Protection)

This Rapid Exchange® purging system that operates on a supply of compressed
instrument air or inert gas. It regulates and monitors pressure within sealed
(protected) enclosure(s), in order to prevent combustible dust accumulation or
remove and prevent flammable gas or vapor accumulations. In Class II Areas, the
system maintains a "safe" (1.0") pressure. In addition, the system includes an
electrical power control unit (EPCU) that monitors system operation and controls
enclosure power. All start-up requirements must be satisfied before the EPCU will
energize power to the enclosure(s). These processes reduce the hazardous
(classified) area rating within the enclosure(s), in accordance with the NEC - NFPA
70, Article 500, NFPA 496 and ISA 12.4.

Product Features

Shipping Weight
38 lb

Temp. Range
-20F to 120F

Supply Pressure Range
5 - 120 psi

Supply requirements
Clean air or inert gas

Safe Pressure Setpoint
.25"/1" @ safe pressure

Safe Pressure Flow Rate
0.1 - 3.5 SCFH - Enclosure integrity determines actual flow rate

Exchange Flow Rate
4 SCFM / 240 SCFH - With regulator set to 60 psi min. during exchange

System Supply Port
1/4" FPT

Enclosure Supply Fitting
1/4" tube fitting

Enclosure Reference Fitting
1/4" tube fitting

EPCU Conduit Port Size
1/2" FPT

EPCU Power Requirements
120 VAC 60Hz 10

EPCU Power Consumption
500mA

Dimensions
20" (H) x 11" (W) x 10.5" (D)
Height & Width dimensions reflect mounting plate measurements. Depth
dimensions reflects overall measurement of system, including components.

Mounting
Side (L/R), Top or Bottom

OPERATION

In accordance with system instructions, start-up requires the air supply to be
engaged and EPCU power to be energized. In Class II Areas, all dust must be
removed from the enclosure(s). The enclosure protection vent (if used) must be
tested and enclosure(s) must be sealed. The EPCU power control switch must be
activated and the system will self-test. The enclosure pressure control regulator is
then used to set a safe reading on the enclosure pressure gauge. In Class II Areas,
power will energize shortly after safe pressure is stable. Loss of safe pressure
causes the EPCU to de-energize power to the protected enclosure(s). All systems
include form "C" contacts for audible or visual alarm systems.


Home

Contact

Products

Print

Close