FEATURES
- Designed to Meet Class 2
Division 1 Protection
- NEMA 4X (IP66) sealed enclosure
- Purge System
- Water proof and dust proof
- Stainless steel construction
- Mid-size footprint
- Flexible mounting options
- Direct or KVM cabling to
host
- LCD screen shielded by a
Tempered Glass Protective
Overlay
CONTACT
HEADQUARTERS
11529 Sun Belt Ct.
Baton Rouge, Louisiana 70809
Phone
800.223.8050
International 001.225.298.0300
Fax
225.297.2440
E-mail
sales@vartechsystems.com
Website
www.vartechsystems.com
_____________________

Material Specifications
Regulator Body
Zinc w/ Enamel Finish
Regulator Handle & Bowl
Polycarbonate
Rapid Exchange Gauge
Aluminum w/ Enamel Finish
Tube Fittings & Valves
316 SS Forged Body
Tubing
316 SS 1/4" .035 Welded
System Nameplates
Silk screened Lexan® & SS
Fastener Hardware
SS Screws & Bolts
Mounting Plate
316 14 Ga #3 Brush SS
EPCU Enclosed Body
Bead Blast Cast Alum.
Enclosure Warning
Nameplate
Silkscreened SS
The VT952ES is a NEMA 4X (IP66) LCD designed to meet Class 2, Div 1 protection. The purge system uses a pressure switch to automatically trigger alarms in case of pressure loss.
Slim and Economical
With its moderate weight and small footprint, the VT952ES series is ideal for
applications where both space and budget are limited.
Durable
The VT952ES monitors is fully enclosed in sealed, NEMA 4X (IP66), easy-open,
stainless steel cases. The chassis has no external vents, so nothing can get
under its skin, including weather, dust, dirt, moisture, oil, chemicals or other
harsh contaminants. A hard-anodized cast aluminum heat exchanger and
internal heat management system keep it cool in environments where ambient
temperatures approach 50°C/122°F -- without using outside air. With its lightweight yet rugged construction, and either pre-cabled or bulkhead connectors, the VT952ES display is easily mounted on walls, stands, arms or other industrial equipment.
The display is available with optional brackets, that conforms to VESA flat panel
mounting standards.
![]()
Display
19 Inch TFT, LCD screen shielded by a
Tempered Glass Protective Overlay
Resolution Capabilities
SXGA
Pixel Format
1280 x 1024*
Standard Connection
VGA, Serial, Power
Enclosure
316 Stainless Steel Sealed Anodized Aluminum Heat Sink
12" Handles
Environmental/Thermal
NEMA 4X (IP66)
Water Proof
Dust Proof
50ºC/122ºF
IP65
![]()
Purge System Mounting to Side (L/R), Top or Bottom
_____________________________________________________________
X Type Purge System w/ Pressure Switch (Class 2, Div 1 Protection)
This Rapid Exchange® purging system that operates on a supply of compressed
instrument air or inert gas. It regulates and monitors pressure within sealed
(protected) enclosure(s), in order to prevent combustible dust accumulation or
remove and prevent fl ammable gas or vapor accumulations. In Class II Areas, the
system maintains a "safe" (1.0") pressure. In addition, the system includes an
electrical power control unit (EPCU) that monitors system operation and controls
enclosure power. All start-up requirements must be satisfied before the EPCU will
energize power to the enclosure(s). These processes reduce the hazardous
(classified) area rating within the enclosure(s), in accordance with the NEC - NFPA
70, Article 500, NFPA 496 and ISA 12.4.
![]()
Shipping Weight
38 lb
Temp. Range
-20F to 120F
Supply Pressure Range
5 - 120 psi
Supply requirements
Clean air or inert gas
Safe Pressure Setpoint
.25"/1" @ safe pressure
Safe Pressure Flow Rate
0.1 - 3.5 SCFH - Enclosure integrity determines actual flow rate
Exchange Flow Rate
4 SCFM / 240 SCFH - With regulator set to 60 psi min. during exchange
System Supply Port
1/4" FPT
Enclosure Supply Fitting
1/4" tube fitting
Enclosure Reference Fitting
1/4" tube fitting
EPCU Conduit Port Size
1/2" FPT
EPCU Power Requirements
120 VAC 60Hz 10
EPCU Power Consumption
500mA
Dimensions
20" (H) x 11" (W) x 10.5" (D)
Height & Width dimensions reflect mounting plate measurements. Depth
dimensions reflects overall measurement of system, including components.
Mounting
Side (L/R), Top or Bottom
OPERATION
In accordance with system instructions, start-up requires the air supply to be
engaged and EPCU power to be energized. In Class II Areas, all dust must be
removed from the enclosure(s). The enclosure protection vent (if used) must be
tested and enclosure(s) must be sealed. The EPCU power control switch must be
activated and the system will self-test. The enclosure pressure control regulator is
then used to set a safe reading on the enclosure pressure gauge. In Class II Areas,
power will energize shortly after safe pressure is stable. Loss of safe pressure
causes the EPCU to de-energize power to the protected enclosure(s). All systems
include form "C" contacts for audible or visual alarm systems.